Bioreactor for inside installation Type STB 21 |
|
|
Technical data:
- Application in local traffic vehicles
- Installation as replacement for receiver tank systems
- For 80 uses per day, including processing of hand washbasin waste water
- Waste disposal interval 4 months
- Dimensions:
900 x 390 x 1965 m
- Weight:
blank 230 kg
full 530 kg
- Power requirements:
400 V AC 50 Hz,
1500 W, 24 V DC, 50 W
- Control: BIC 2003
- Installation concept: Floor mounting
|
|
|

|
Bioreactor for inside installation Type STB 22 with 200 l water tank
Technical data:
- Application in local traffic vehicles
- Installation as replacement for receiver tank systems
- For 120 uses per day including processing of hand washbasin waste water
- Waste disposal interval 4 months
- Dimensions: 1200 x 630 x 1610 mm
- Weight:
empty 280 kg
full 700 kg
- Power requirements: 400 V AC 50 Hz,
1500 W, 24 V DC, 50 W
- Control: BIC 2003
- Installation concept: Floor mounting
Water feed to the sanitary cell is gravitational. The water tank is mounted above the lid of the bioreactor by means of a console. The two tanks form a unit which may be separated for purposes of assembly, maintenance or repair.
|
|